Aardingtesters 3P/4P

SKU-short: CA64
Merk: Chauvin Arnoux

Hoofdspecificaties

  • Geleverd met 1 externe netlader, software + snoer voor optische communicatie/USB, gebruikshandleidingen en 5 etiketten.
  • 4 in 1: 3-pole and 4-pole measurements, Resistivity (Wenner + Schlumberger methods), Earth coupling, Continuity & resistance.
  • Large backlit LCD screen and a battery which is rechargeable with an external charger connected to the mains or to a vehicle cigarette lighter.
  • Equipped with a function for direct, ordered storage of the measurement results.
  • A USB communication output can be used to export the data onto a PC in order to process them with the Ground Tester Transfer software.
  • The CA6470N offers approximately 10 times greater accuracy thanks to its four-pole earth measurements. This method allows measurements of low earth resistance values, which are essential to meet the requirements of power distribution and transmission companies.
  • It guarantees the reliability of measurements carried out by traditional stake-based methods.
  • Self-diagnosis when each measurement starts, so that any faults liable to affect the measurements (bad connections or presence of disturbance signals) are indicated.
  • Extensive measurement ranges: 0.001 ? to 100 k?.
  • Adjustment of the measurement frequency between 41 Hz and 512 Hz (3P & 4P measurements).
  • For earth coupling measurements, simply perform the 3 succesive measurements required and the tester then calculates the coupling coefficient automatically.
  • For soil resistivity measurements, simply program the distances used for the measurement and the instrument automatically calculates r using the Wenner or Schlumberger methods.
  • Power supply: NiMh rechargeable battery with external charger.
  • IP53 protection.
  • Compliant with IEC 61557 -1 -4 -5.
  • Safety: IEC 61010 50V CAT IV.
Toon meer

Momenteel zijn er geen online aankopen mogelijk.
Wilt u een artikel bestellen of een offerte aanvragen?
Neem contact met ons op via e-mail op info@sadinter.nl of telefonisch op +31 (0) 182 74 32 44.

Gegroepeerde productitems
REF Depth Measuring Range No. Outputs Operation Protection Safety Voorraad
CA6470N Mem.: 512 mes. 41 à 512Hz 1xUSB Méthode 3P/4P IP53 IEC 61010 / CAT IV 50V
délai sur demande
CA6471 Mem.: 512 mes. 41 à 512Hz 1xUSB Méthode 3P/4P + pinces
délai sur demande
CA6472 Mem.: 512 mes. 41 à 5078Hz 1xUSB Méthode 3P/4P + pinces + pylones
délai sur demande
CA6474
délai sur demande

Momenteel zijn er geen online aankopen mogelijk.
Wilt u een artikel bestellen of een offerte aanvragen?
Neem contact met ons op via e-mail op info@sadinter.nl of telefonisch op +31 (0) 182 74 32 44.

Omschrijving

  • Geleverd met 1 externe netlader, software + snoer voor optische communicatie/USB, gebruikshandleidingen en 5 etiketten.
  • 4 in 1: 3-pole and 4-pole measurements, Resistivity (Wenner + Schlumberger methods), Earth coupling, Continuity & resistance.
  • Large backlit LCD screen and a battery which is rechargeable with an external charger connected to the mains or to a vehicle cigarette lighter.
  • Equipped with a function for direct, ordered storage of the measurement results.
  • A USB communication output can be used to export the data onto a PC in order to process them with the Ground Tester Transfer software.
  • The CA6470N offers approximately 10 times greater accuracy thanks to its four-pole earth measurements. This method allows measurements of low earth resistance values, which are essential to meet the requirements of power distribution and transmission companies.
  • It guarantees the reliability of measurements carried out by traditional stake-based methods.
  • Self-diagnosis when each measurement starts, so that any faults liable to affect the measurements (bad connections or presence of disturbance signals) are indicated.
  • Extensive measurement ranges: 0.001 ? to 100 k?.
  • Adjustment of the measurement frequency between 41 Hz and 512 Hz (3P & 4P measurements).
  • For earth coupling measurements, simply perform the 3 succesive measurements required and the tester then calculates the coupling coefficient automatically.
  • For soil resistivity measurements, simply program the distances used for the measurement and the instrument automatically calculates r using the Wenner or Schlumberger methods.
  • Power supply: NiMh rechargeable battery with external charger.
  • IP53 protection.
  • Compliant with IEC 61557 -1 -4 -5.
  • Safety: IEC 61010 50V CAT IV.